Materials in contact with fluid
Nitrile
Nylon 6/6
Zinc plated steel
Operating position
Any position
Motor power kW
0.75 kW/1 hp at 110 V AC, 1 phase
1.1 kW/1.5 hp at 110 V AC, 3 phases
1.5 kW/2 hp at 230 V AC, 1 phase
1.5 kW/2 hp at 400 V AC, 1 phase
2.2 kW/3 hp at 230 V AC, 3 phases
2.2 kW/3 hp at 400 V AC, 3 phases
Adjustable range of switching point on falling pressure
0.3…3.4 bar
Adjustable range of switching point on rising pressure
1.4…4.6 bar
Possible differential minimum at low setting
1 bar
Possible differential minimum at high setting
1.2 bar
Possible differential maximum at low setting
2.1 bar
Possible differential maximum at high setting
2.3 bar
Maximum permissible accidental pressure
8 bar
Maximum permissible pressure - per cycle
5.75 bar
Destruction pressure
20 bar
Pressure actuator
Diaphragm
Electrical durability
100000 cycles, operating rate <10 cyc/mn
Mechanical durability
1000000 cycles
Terminal block type
4 terminals
Possible differential minimum at middle setting
1.1 bar
Possible differential maximum at middle setting
2.2 bar
Maximum operating rate
10 cyc/mn
[Ui] rated insulation voltage
500 V conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
Terminals description ISO n°1
(3-4)NC
(1-2)NC